Quality
A systematic process followed to achieve more than customer expectations with stringent checkout of Manufacturing activities right from the receipt of raw material to dispatch of castings . The System covers Equipment, Personnel and Inspection methods and it complies with National & International Standard requirements. The documents are subjected to periodic audits for continual improvement.
Spectrometer
Spectrometer of Optical emission type to analyse 31 elements including Nitrogen ensures required Chemical composition before pouring.
Certified reference samples are used to ensure consistency in equipment accuracy.
Positive Material Identifier
PMI is used for sorting of scrap and alloys swiftly. It is also used to Confirm the grade of castings before dispatch.
Microscope
Microscope with 800X Magnification linked with Dewinter Plus image Analyzer facilitates to analyze and confirm the microstructure and enables submission of report with captured images.
Ferritoscope
Use of Ferrite scope enables to check the Ferrite number at any spot on the castings without any destruction. Certified reference samples are used to ensure the instrument accuracy.
Rad Check Meter
Rad Check meter is available to check the radioactive contamination level to ensure Contamination free scrap usage and to confirm contamination free casting supply.
Universal Testing Machine
Computerised Universal Testing Machine with a capacity of 200 KN available to check the Mechanical properties. Electronic Extensometer used to evaluate the proof stress.
Impact Testing Machine
Impact Testing Machine available to check the impact strength at various temperatures upto a sub zero level of -196°C.Equipment for Confirming the testing Temperature level is also available.
Hardness Testing Machine
Rockwell Hardness Testing Machine available to ensure the hardness level in specimens.
Brinell Hardness is checked by using an attachment in Universal Testing Machine.
Magnetic Particle Inspection
Magnetic Particle Testing facility is available with prod method in both Fluorescent and Non Fluorescent medium. Testing is carried out in both dry and wet method.
Liquid Penetrant Inspection
Solvent removable Non Fluorescent medium used for Penetrant test
Ultrasonic Testing
Ultrasonic testing Equipment available with testing range upto 5000mm with a maximum frequency of 10MhZ